Nortel DMS-100 Series Maintenance Manual page 194

Subscriber carrier module-100s
Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

6-30 Alarm clearing procedures
PM SMS
minor
(continued)
26
27
28
29
30
297-8231-550 Standard 09.01 August 1998
To check for fault indicators, type
>QUERYPM FLT
and press the Enter key.
If PM load mismatch with CC
continues to appear
does not appear
Determine if the card replaced is the NT6X78.
If card replaced is
NT6X78
other
To manually busy the inactive unit, type
>BSY UNIT unit_no
and press the Enter key.
where
unit_no
is the number of the inactive unit
Go to step 32.
To load the CLASS moduem resource circuit pack (CMR) card, type
>LOADPM UNIT unit_no CC CMR
and press the Enter key.
where
unit_no
is the number of the unit that contains the defective CMR card
If load
passes
fails
Reload the inactive unit if any of the following cards is replaced:
NTMX7,
Do
step 45
step 46
Do
step 29
step 30
Do
step 33
step 45