Nortel DMS-100 Series Maintenance Manual page 175

Subscriber carrier module-100s
Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

Example of a MAP response:
Node is ISTb
One or both units inservice trouble
Unit 0
The following inservice troubles exist:
Static data mismatch with CC
Unit 1
The following inservice troubles exist:
Static data mismatch with CC
If
card list appears at the MAP
display
P-side links are out of service
static data does not match with
the CC
PM load mismatch with inventory
table
data is out of date
the above conditions do not occur
11
To busy the inactive unit, type
>BSY UNIT unit_no
and press the Enter key.
where
unit_no
is the number of the inactive unit
12
To load the inactive unit, type
>LOADPM UNIT unit_no CC DATA
and press the Enter key.
where
unit_no
is the number of the inactive unit
If LOADPM
passes
fails
DMS-100 Family SMS Maintenance Manual XPM10 and up
Alarm clearing procedures 6-11
major
(continued)
Do
step 28
step 31
step 14
step 16
step 11
step 26
Do
step 13
step 37
PM SMS