When the system detects a fault, the system can trigger an audible alarm. To
access the MTC level of the MAP display and silence the alarm, type
>MAPCI;MTC;SIL
and press the Enter key.
To access the PM level of the MAP screen to locate the SMS that is ISTb, type
>PM;DISP STATE ISTB SMS
and press the Enter key.
Example of a MAP response:
ISTb SMS:
1
To access the ISTb SMS, type
>POST SMS sms_no
and press the Enter key.
where
sms_no
is the number of the SMS that appears in step 2
Example of a MAP response:
SMS
SysB
ManB
PM
3
SMS
0
SMS 0 ISTb
Links_OOS:
Unit0:
Act
ISTb
Unit1:
Inact InSv
If
one unit is SysB
one unit is CBsy
one unit is ManB
both units are InSv
both units are ISTb
one unit is ISTb and inactive
one unit is ISTb and active
Offl
CBsy
ISTb
0
1
0
0
0
0
CSide 0, PSide 0
Do
step 26
step 24
step 4
step 10
step 10
step 10
step 5
InSv
2
13
1
7