6-18 Alarm clearing procedures
PM SMS
major
(continued)
39
40
297-8231-550 Standard 09.01 August 1998
CAUTION
Service disruption. The PM can drop calls.
If the system prompts you to confirm a cold SWACT,
perform this activity in a period of low traffic. The
PM will end all calls, including data calls.
To switch the activity of the units, type
>SWACT
and press the Enter key.
The system determines the type of SWACT the system can perform, a warm
SWACT or a cold SWACT. The system displays a confirmation prompt for the
selected SWACT.
If SWACT
cannot continue
can continue
Do not switch activity of the units. To reject the switch, type
>NO
and press the Enter key.
The system discontinues the SWACT. Return to step 39 in a period of low
traffic.
Do
step 40
step 41