Nortel DMS-100 Series Maintenance Manual page 305

Subscriber carrier module-100s
Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

18
Obtain further assistance in replacing this card by contacting the personnel
responsible for higher level of support.
At the frame
19
Remove the sign from the active SMS unit.
20
Send any faulty cards for repair according to local procedure.
21
Record the following items in office records according to local policy:
date the card was replaced
serial number of the card
symptoms that prompted replacement of the card
22
You have successfully completed this procedure. Return to the maintenance
procedure that directed you to this card replacement procedure and continue as
directed.
23
For further assistance with switch of activity, contact the personnel responsible
for the next level of support.
Note: If the system recommends using the SWACT command with the FORCE
option, consult office personnel to determine if use of the FORCE option is
advisable.
DMS-100 Family SMS Maintenance Manual XPM10 and up
Card replacement procedures 7-99
SMS
NT6X86
NT6X86
SMS
(continued)
(end)