Nortel DMS-100 Series Maintenance Manual page 423

Subscriber carrier module-100s
Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

Clearing an SMS alarm
Alarm condition
Major
(continued)
Possible cause
A C-side card has faults.
Power converter card has
faults.
—continued—
DMS-100 Family SMS Maintenance Manual XPM10 and up
Troubleshooting chart 10-3
Action
Proceed as follows:
1
Silence the alarm.
2
Identify the SMS unit in
the ISTb condition.
3
Post the SMS unit in the
ISTb condition.
4
Identify the problems with
the posted SMS unit.
5
Busy and test the posted
SMS unit.
6
Return to service the
posted SMS unit.
Proceed as follows:
1
Silence the alarm.
2
Identify the SMS unit in
the ISTb condition.
3
Post the SMS unit in the
ISTb condition.
4
Identify the problems with
the posted SMS unit.
5
Busy and test the posted
SMS unit.
6
Return to service the
posted SMS unit.