7-110 Card replacement procedures
NT7X05
SMS
(continued)
Replacing an NT7X05 card in an SMS
At your Current Location
1
2
At the MAP display
3
297-8231-550 Standard 09.01 August 1998
Proceed only if you were either directed to this card replacement procedure
from a step in a maintenance procedure, are using the procedure to verify or
accept cards, or were directed to this procedure by your maintenance support
group.
CAUTION
Loss of service
When replacing a card in the SMS ensure the unit
where you are replacing the card is INACTIVE and
the mate unit is ACTIVE.
Obtain a replacement card. Ensure the replacement card has the same
product equipment code (PEC) including suffix, as the card to be removed.
Access the PM level and post the SMS by typing
>MAPCI;MTC;PM;POST SMS sms_no
and pressing the Enter key.