Nortel DMS-100 Series Maintenance Manual page 196

Subscriber carrier module-100s
Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

6-32 Alarm clearing procedures
PM SMS
minor
(continued)
33
34
35
36
297-8231-550 Standard 09.01 August 1998
To test the CMR card, type
>TST UNIT unit_no CMR
and press the Enter key.
where
unit_no
is the number of the unit that contains the CMR card that has defects
If test
passes
fails, and card list appears
fails, but no card list appears
Check the card list that appears at the MAP display. The card with possible
defects appears on the list first.
Example of a MAP display:
Site Flr RPos
Bay_id Shf Description Slot EqPEC
HOST
00
M07
SME 00
HOST
00
M07
SME 00
HOST
00
M07
SME 00
HOST
00
M07
SME 00
If all cards in the card list
are replaced
are not replaced
Go to Card Replacement Procedures for the first, or next, card on the list.
When you return from the card replacement procedures, go to step 27 of this
procedure.
To return the inactive unit to service, type
>RTS UNIT unit_no
and press the Enter key.
where
Do
step 37
step 34
step 45
51
SMS : 000
51
SMS : 000
65
SMS : 000
51
SMS : 000
Do
step 45
step 35
08
6X45
22
6X40
22
6X40
12
6X45