unit_no
is the number of the inactive unit
If RTS
passes
fails
8
CAUTION
Service disruption. Calls can drop!
If the system prompts you to confirm a cold SWACT,
perform this activity only during a period of low
traffic. The system drops all calls that this PM
handles including data calls.
To switch the activity of the units, type
>SWACT
and press the Enter key.
The system determines the type of SWACT (warm or cold) that the system can
perform. The system displays a confirmation prompt for the selected SWACT.
If SWACT
cannot continue at this time
can continue at this time
9
Do not switch activity of the units. Reject the switch, type
>NO
and press the Enter key.
The system does not continue the switch of activity.
Return to step 8 during a period of low traffic.
10
To switch the activity of the unit, type
>YES
and press the Enter key.
The system runs a pre-SWACT audit to determine if the inactive unit can accept
activity correctly.
DMS-100 Family SMS Maintenance Manual XPM10 and up
Alarm clearing procedures 6-25
minor
(continued)
Do
step 46
step 45
Do
step 9
step 10