Data transfer within the PLC
F0_MV
The 16-bit data or 16-bit equivalent constant specified by s is copied to the 16-bit area specified by
Description
d, if the trigger EN is in the ON-state.
This instruction also exists as a P instruction (for FP2/2SH, FP3/5, FP10/10SH PLC types), which
is only executed at the rising edge of the EN trigger. Select [Insert P instruction] from the
"Instructions" pane if you require a P instruction. To facilitate reuse, the instruction then appears
under "Recently used" in the pop-up menu. Press <Ctrl>+<Shift>+<v> within the programming
area to open the list of recently used elements.
Instead of using this FP instruction, we recommend using the related IEC instruction MOVE (see
page 59). Please refer also to Advantages of the IEC instructions in the online help.
Availability of F0_MV (see page 1320)
PLC types
Data types
Variable
Data type
s
ANY16
d
The variables s and d have to be of the same data type.
Operands
For
WX
s
-
d
Explanation with example value 16#0089
source
bit
15
s
0
destination
bit
15
d
0
Destination value in this example: 16#0089
In this example the function has been programmed in ladder diagram (LD) and structured text
Example
(ST).The same POU header is used for all programming languages.
806
16-bit data move
Function
source 16-bit area
destination 16-bit area
Relay
T/C
WY
WR
WL
SV
WY
WR
WL
SV
.
.
12
11
.
.
8
0 0
0
0
0
0
0
.
.
12
11
.
.
8
0 0
0
0
0
0
0
Register
EV
DT
LD
FL
EV
DT
LD
FL
7
.
.
4
3
.
.
0
1
0
0
0
1
0
0
1
7
.
.
4
3
.
.
0
1
0
0
0
1
0
0
1
Constant
dec. or hex.
-