High-speed counter instructions
HscInfo_ReadElapsed
Value
This instruction reads the elapsed value from the high-speed counter channel specified by
Description
iChannel.
See also:
Tool instructions: overview of high-speed counter instructions
HscControl_WriteElapsedValue (see page 1152)
HscControl_ElapsedValueReset (see page 1145)
HscControl_ElapsedValueContinue (see page 1143)
FP instructions Writing and reading the elapsed value (see page 894)
see page 1327
PLC types
Data types
Variable
iChannel
Output variable
In this example the function has been programmed in ladder diagram (LD) and structured text (ST).
Example
The same POU header is used for all programming languages.
POU header
All input and output variables used for programming this function have been declared in the POU
header.
Body
LD
ST
When programming with structured text, enter the following:
if
(bReadElapsedValue)
diElapsedValue
end_if;
1164
Reads elapsed value from high-speed counter channel
Data type
Function
INT
High-speed counter channel:
FP
: 0, 2
FP-X R: 0, 1
FP-X 16K C14T: 0, 1, 2
FP-X 32K C30T, C60T: 0, 1, 2, 3
FP0R: 0, 1, 2, 3
FP0: 0, 1
FP-e: 0, 1
DINT
Stores the elapsed value from the channel specified by iChannel
then
:=
HscInfo_ReadElapsedValue(iChannel
:= iChannel);