Panasonic FP-I4C Quick Start Manual
Panasonic FP-I4C Quick Start Manual

Panasonic FP-I4C Quick Start Manual

Programmable controller fp industry 4.0 communicator
Hide thumbs Also See for FP-I4C:

Advertisement

Quick Links

ACGM0162V1EN
2019.07
www.panasonic-electric-works.com
Programmable Controller
Quick Start Guide
FP Industry 4.0 Communicator
FP-I4C

Advertisement

Table of Contents
loading

Summary of Contents for Panasonic FP-I4C

  • Page 1 Programmable Controller Quick Start Guide FP-I4C FP Industry 4.0 Communicator ACGM0162V1EN 2019.07 www.panasonic-electric-works.com...
  • Page 2 This manual and everything described in it are copyrighted. You may not copy this manual, in whole or part, without written consent of Panasonic Electric Works Europe AG (PEWEU). PEWEU pursues a policy of continuous improvement of the design and performance of its products.
  • Page 3: Table Of Contents

    4.4 Connecting the power supply......................27 5 Wiring............................29 5.1 Connecting the PLC TOOL port using the cable AIGT8192............29 5.1.1 Using the PLC TOOL port with the FP-I4C COM1..............29 5.1.2 Using the PLC TOOL port with the FP-I4C COM2..............29 FP-I4C...
  • Page 4 Table of contents 5.2 Connecting the PLC COM......................30 5.2.1 Using the PLC COM port with the FP-I4C COM1..............30 5.2.2 Using the PLC COM port with the FP-I4C COM2..............31 5.3 Connecting RS485 to Eco-POWER METER..................31 6 First steps..........................33 6.1 Getting started..........................33 6.2 The Ethernet network........................
  • Page 5: Introduction

    Introduction BEFORE YOU START Make sure that you have worked through the First Steps before you try out more complex functions of the FP-I4C. Please read the following safety instructions and also the section on mechanical installation carefully. Safety measures After installing the unit, make sure to use it within the range of the general specifications: •...
  • Page 6: Warnings Used In This Manual

    Indicates a hazardous situation which, if not avoided, could result in serious or moderate injury. CAUTION Indicates a hazardous situation which, if not avoided, could result in minor or moderate injury. NOTICE Indicates a property damage message. System requirements HMWIN Studio has the following system requirements: FP-I4C...
  • Page 7 Microsoft Windows® 7, Windows® 8.x or Windows® 10 • Hard disk with at least 500MB free disk space, 512MB RAM, Ethernet connection To configure the device a standard browser is needed: e.g. Microsoft Edge, Mozilla Firefox, Google Chrome, Apple Safari, Opera. FP-I4C...
  • Page 8: Functional Overview

    HMWIN Studio. FP-I4C functions The FP-I4C works as an interface between a LAN or a WAN network (Internet/ Intranet) and all PLCs of the FP series. The following main features are supported: RS232C/ Ethernet interface (see separate manual): •...
  • Page 9: Fp-I4C Block Diagram

    PLC data or logged data to a remote FTP server. Data logger: • The FP-I4C unit can log PLC data and store it in the internal memory or send it via FTP. Secure data transmission and authentication: • The FP-I4C unit can communicate via OpenVPN to get an encrypted and secure data transmission and authentication.
  • Page 10 2 Functional overview FP-I4C...
  • Page 11: Hardware Description

    • 16-pin spring force plug Comments: The FP-I4C network settings will be configured via web page which can be displayed in a standard browser. Parts and functions Below are two illustrations of the FP-I4C's parts and their functions:...
  • Page 12 Binary inputs as optional unit functions. Pull-up design (leave it open or wire a short to the GND pins) (7) COM2 RS232/RS485: used for PLC communication or transparent redirect services (8) 24V DC, use Panasonic power cable (AFPG805) Brown = +24V DC Blue = GND...
  • Page 13: Leds

    Within the housing on the top side you can find a small tact switch. You can use a flat/dulled spike or a paperclip to operate the tact switch. The reset tact switch can be used to restart the unit. FP-I4C...
  • Page 14: 3.3.2.2 Reset To Default Settings

    The orange LED (USR) should flash like a heart beat (1 heart beat per second). Now press the reset tact switch again for at least 6 seconds, then release. The unit will set default values and then it restarts completely. All user data are removed. FP-I4C...
  • Page 15: Technical Data

    3.4 Technical data Technical data Feature Description Product number FP-I4C PLC connection 1 COM1: RS232C via 16-pin spring force plug: Phoenix contact product: MC0.5/8-ST-2,5 PLC connection 2 COM2: RS232C/RS485 via 16-pin spring force plug: Phoenix contact product: MC0.5/8-ST-2,5 Power supply 24V DC.
  • Page 16: Targeted Peripheral List Of The Usb Host Port

    Manufacturer Model Vendor ID Product Description Speed Panasonic Electric GT series 0x0986 0x0310 Panasonic GT USB USB 2.0 Full Works, Ltd. driver ver. 1.0 speed Panasonic Electric PLC FP0H, 0x0986 0x0320 Panasonic FP USB 2.0 Full Works, Ltd.
  • Page 17: Installation

    ‒ Always install the unit orientated with the Ethernet port facing outward on the top in order to prevent the generation of heat. ‒ Do not install the unit above devices which generate heat, such as heaters, transformers or large scale resistors. FP-I4C...
  • Page 18 COM1 F1 F2 COM2 S/- R/+ S/- R/+ G2 G2 (1) DIN rail Installation space • Leave at least 50mm of space between the wiring ducts of the unit and other devices to allow heat radiation and unit replacement. FP-I4C...
  • Page 19 S/- R/+ S/- R/+ G2 G2 (1) 50mm or more • Maintain a minimum of 100mm between devices to avoid adverse affects from noise and heat when installing a device or panel door to the front of the FP-I4C unit. FP-I4C...
  • Page 20: General Installation Procedure

    (1) 100mm or more (2) Other device or panel door • Keep the first 100mm from the front surface of the FP-I4C unit open in order to allow room for programming tool connections and wiring. General installation procedure Please install the FP-I4C in the following order:...
  • Page 21: Mechanical Installation

    You can align the pins and holes in the four corners of the control unit and expansion unit, and insert the pins into the holes so that there is no gap between the units However you need not necessarily connect the FP-I4C in this way. FP-I4C...
  • Page 22 4 Installation (1) Control unit (2) FP-I4C Press down the expansion hooks raised in step 2 to secure the unit Note Make sure that the FP-I4C is the last unit attached. Otherwise the CPU cannot communicate with the expansion units. FP-I4C...
  • Page 23: Attachment To Din Rails

    Fit the upper hook of the FP-I4C onto the DIN rail. (1) Mounting panel (2) DIN rail Without moving the upper hook, press on the lower hook to fit the FP-I4C into position. (1) Mounting panel (2) DIN rail 4.3.3 Removal from a DIN Rail You can easily remove the FP-I4C from a DIN rail as described below.
  • Page 24: Installation Using Fp0 Slim Type Mounting Plate

    4 Installation Lift up the FP-I4C unit and remove it from the rail. (1) DIN rail (2) DIN rail attachment lever 4.3.4 Installation using FP0 slim type mounting plate Use M4 size pan-head screws to attach the FP0 slim type mounting plate (AFP0803) to the mounting panel.
  • Page 25 Fit the upper hook of the FP-I4C onto the FP0 slim type mounting plate (1) FP0 slim type mounting plate AFP0803 Without moving the upper hook, press on the lower hook to fit the FP-I4C into position. (1) FP0 slim type mounting plate AFP0803 When using an expansion unit, join all of the FP0 slim type mounting plates to be connected.
  • Page 26: Installation Using Fp0 Flat Type Mounting Plate

    AFP0804 (1) FP0 flat type mounting plate AFP0804 (2) Screw (3) Mounting panel Raise the expansion hooks on the top and bottom of the unit. Install the FP-I4C on the FP0 flat type mounting plate FP-I4C...
  • Page 27: Connecting The Power Supply

    (1) DIN rail (2) FP0 flat type mounting plate AFP0804 Note An FP-I4C with an attached FP0 flat type mounting plate can also be installed sideways on a DIN rail. Connecting the power supply Use the power supply cable (AFPG805) that comes with the unit to connect the power supply.
  • Page 28 When connecting the power supply (class 2 circuit) make sure the polarity (+/-) is correct. The FP-I4C unit and the PLC have to be supplied by THE SAME power supply unit. If power is supplied, the green POWER LED will be ON after self-test.
  • Page 29: Wiring

    (3) Orange, green: G (COM1) to pin 3 (4) PLC TOOL port mini-DIN, 5-pin male (5) FP-I4C 16-pin connector 5.1.2 Using the PLC TOOL port with the FP-I4C COM2 Wire the PLC TOOL port with the FP-I4C 16-pin connector (COM2). FP-I4C...
  • Page 30: Connecting The Plc Com

    FP0R, FPS, FP-X, FP0H, FP7: Use either COM1 or COM2 for communication (depending on the PLC interface settings) 5.2.1 Using the PLC COM port with the FP-I4C COM1 Wire the PLC COM port with the FP-I4C 16-pin connector (COM1) S (COM1) R (COM1) G (COM1)
  • Page 31: Using The Plc Com Port With The Fp-I4C Com2

    5.3 Connecting RS485 to Eco-POWER METER 5.2.2 Using the PLC COM port with the FP-I4C COM2 Wire the PLC COM port with the FP-I4C 16-pin connector (COM2) S (COM1) R (COM1) G (COM1) G (COM1) S/ - (COM2) R/ + (COM2)
  • Page 32 5 Wiring Terminal number Functions + connected to R/ + (COM2) - connected to S/ - (COM2) FP-I4C...
  • Page 33: First Steps

    FP-I4C. The FP-I4C can be connected to an existing Ethernet network. It is also possible to set up a separate network for the FP-I4C. The computer can also be directly connected to the FP-I4C by using a special "crossover" Ethernet cable.
  • Page 34: Determination Of The Ip Configuration

    The IP address consists of 4 numbers (0 to 255). The first numbers define the network address, the other numbers define the participant's address. The IP address of the FP-I4C can be fixed or it can be allocated dynamically by a DHCP server.
  • Page 35: Configure The Functions Of Your Choice

    Preinstalled passwords (page 38) Configure the functions of your choice After having connected to the FP-I4C unit with a browser you can start to activate the functions. Please change in the address line of your browser the https://192.168.0.1/machine_config to https://192.168.0.1/fp_config to enable the FP-I4C unit functions.
  • Page 36 Each interface should be configured with a communication protocol. Panasonic PLCs use MEWTOCOL by default. • With Autobaud a Panasonic PLC is tested with different baud rates to find the right connection speed (using MEWTOCOL). • The default PLC interface should be set to the interface which is used for your PLC. In a RS485 network the PLC station address is important to communicate with the correct PLC.
  • Page 37: Test The Plc Connection

    HMWIN Studio an Ethernet interface connected to the IP address 127.0.0.1 instead. Test the PLC connection To test if the PLC communication is established you can use the “Test connection” button which is available on the “Interface settings”. FP-I4C...
  • Page 38: Preinstalled Passwords

    User names and passwords can be set in the configuration pages within a browser. Overview of the default passwords: Service User Name: Password: Configuration / SSH (if enabled) admin admin SSH (if enabled) standard user user user FTP server (if enabled) for logged data FP-I4C...
  • Page 39 6.8 Preinstalled passwords Note • Please note: If you forget your passwords, you have to reset the FP-I4C to the default settings. • Always change all passwords to have a secure device within your network. Allowed characters for passwords: All letters, numbers and special characters (e.g. #!$...).
  • Page 40: Record Of Changes

    7 Record of changes Record of changes Manual No. Date Description of Changes ACGM0162V1EN July 2019 First European Edition FP-I4C...
  • Page 41: Panasonic Hotline

    6.8 Preinstalled passwords Panasonic hotline Should you have any problems, we would like to assist you as fast and effectively as possible. So if you have questions that cannot be clarified by the manuals or online help, please call your sales office:...
  • Page 42 8 Panasonic hotline • Asia: http://panasonic-denko.co.jp/ac/e/ • Europe: techdoc.peweu@eu.panasonic.com. You can help us by having the following data at hand: Your product’s serial number and version number. Both numbers are printed on the • original disks. The version number is also indicated in the “Help” > “About ...” menu item.
  • Page 43: Copyright

    6.8 Preinstalled passwords Copyright V2.841 Copyright ã 1995–2019 Panasonic Electric Works Europe AG Robert-Koch-Straße 100, 85521 Ottobrunn, Germany Last modified on: 2019-07-18 FP-I4C...

Table of Contents