High-speed counter instructions
HscControl_Counting
Disable
This instruction disables counting on the high-speed counter channel specified by iChannel. Bit 1
Description
of the high-speed counter control code (see page 891) is set to TRUE.
See also:
Tool instructions: overview of high-speed counter instructions
HscControl_CountingEnable (see page 1141)
HscInfo_IsCountingDisabled (see page 1159)
To add an enable input and enable output to the instruction, select [With EN/ENO] from the
"Instructions" pane (LD, FBD or IL editor). To reuse an instruction select "Recently used" from the
context menu or press <Ctrl>+<Shift>+<v> in the programming window.
see page 1327
PLC types
Data types
Variable
iChannel
In this example the function has been programmed in ladder diagram (LD) and structured text (ST).
Example
The same POU header is used for all programming languages.
POU header
All input and output variables used for programming this function have been declared in the POU
header.
Body
When the variable bDisableCounting changes from FALSE to TRUE, counting on the channel
specified by iChannel is disabled.
LD
1140
Disables counting on a high-speed counter channel
Data type
Function
INT
High-speed counter channel:
FP
: 0, 2
FP-X R: 0, 1
FP-X 16K C14T: 0, 1, 2
FP-X 32K C30T, C60T: 0, 1, 2, 3
FP0R: 0, 1, 2, 3
FP0: 0, 1
FP-e: 0, 1