F153_RMWT
Writes data into the specified intelligent unit of the MEWNET-F slave station.
Description
s1 stores the control data for the configuration of the Master and Slave units in the network. n
words, beginning at the address in the CPU specified by s2, are written to the intelligent unit of the
Slave unit beginning at the shared memory address number specified by d.
Specifications of s1:
s1 higher word
Bit
s1 high word
s1 lower word
Bit
s1 low word
Reference:
This instruction also exists as a P instruction (for FP2/2SH, FP3/5, FP10/10SH PLC types), which
is only executed at the rising edge of the EN trigger. Select [Insert P instruction] from the
"Instructions" pane if you require a P instruction. To facilitate reuse, the instruction then appears
under "Recently used" in the pop-up menu. Press <Ctrl>+<Shift>+<v> within the programming
area to open the list of recently used elements.
Availability of F153_RMWT (see page 1321)
PLC types
Data types
Variable
Data type
DWORD
s1
ANY16
s2
INT
n
ANY16
d
The variables s2 and d have to be of the same data type.
Data write into the slave station
· · ·
· ·
·
·
15
12 11
8 7
Bank No.
(16#00 to 16#FF if
(16#00 to 16#1F,
there is a bank to
FP3: to 16#17)
specify, otherwise
16#00)
· · ·
· ·
·
·
15
12 11
8 7
Master station No.
Slave station No.
(16#01 to 16#04)
(16#01 to 16#20)
Intelligent unit with bank
Name
FP3 expansion data memory
unit
Function
stores control data for Master/Slave configuration
starting 16-bit area in CPU where words are read
number of words to be read and then written to the Slave unit
(max. 32 words)
starting memory address number in the intelligent unit where
words are written
· ·
4 3
0
Slot No.
· ·
4 3
0
Order Number
AFP32091
AFP32092
Data transfer via network
795