Data transfer within the PLC
F191_DMV3
The function copies three 32-bit data values at inputs s1, s2 and s3 to an ARRAY with three
Description
elements that is returned at output d.
This instruction also exists as a P instruction (for FP2/2SH, FP3/5, FP10/10SH PLC types), which
is only executed at the rising edge of the EN trigger. Select [Insert P instruction] from the
"Instructions" pane if you require a P instruction. To facilitate reuse, the instruction then appears
under "Recently used" in the pop-up menu. Press <Ctrl>+<Shift>+<v> within the programming
area to open the list of recently used elements.
Availability of F191_DMV3 (see page 1322)
PLC types
To transfer two 32-bit data types, use either the F8_DMV2 (see page 817) or
P8_DMV2 instruction.
Data types
Variable
Data type
ANY32
s1, s2, s3
ARRAY [0..2]
d
ofANY32
The variables s1, s2, s3 and d have to be of the same data type.
Operands
For
DWX DWY DWR
s1,s2,s3
d
In this example, the same POU header is used for all programming languages. For an example
Example
using IL (instruction list), please refer to the online help.
POU header
All input and output variables used for programming this function have been declared in the POU
header.
Body
When the variable start is set to TRUE, the function is carried out.
856
Three 32-bit data move
Function
source 32-bit area
destination, lower 32-bit area of 96-bit area
Relay
DWL
DSV
-
DWY DWR
DWL
DSV
T/C
Register
DEV
DDT
DLD
DFL
DEV
DDT
DLD
DFL
Constant
dec. or hex.
-