Panasonic FP Series Programming Manual page 971

Hide thumbs Also See for FP Series:
Table of Contents

Advertisement

FP-e display instructions
F180_SCR
This instruction sets up the screen display in the normal mode (N) and switch mode (S) of the FP-e
Description
unit.
Availability of F180_SCR (see page 1335)
PLC types
Data types
Variable
Data type
ANY16
s1
ARRAY [0..2] OF
s2
INT, WORD
s3
ANY16
s4
Operands
For
WX
s1
WX
s2
WX
s3
-
s4
Error flags
No.
IEC address
R9007
%MX0.900.7
R9008
%MX0.900.8
 Special register "DT9***" cannot be specified for the lower section
display data "s4."
 This instruction cannot be used in an interrupt program.
Detailed information, please refer to the online help:
Examples of control register
ASCII code and its display
7-segment data and its display
970
Screen display instruction
Function
Specifies "s1" registration screen
Specifies the head of the screen display control data (3
words).
Specifies the data displayed in the upper section.
Specifies the data displayed in the lower section.
Relay
T/C
WY
WR
-
SV
WY
WR
-
SV
WY
WR
-
SV
WY
WR
-
SV
Set
If
permanently
for an instant
Register
EV
DT
IX
IY
EV
DT
IX
IY
EV
DT
-
-
EV
DT
IX
IY
 the area specified using the Index modifier
exceeds the limit.
 the value for "s1" or "s2" is outside of the
range specified.
Constant
dec. or hex.
-