Pulse output instructions
The status of the high-speed counter control flag or pulse output control flag may
change while a scan is being carried out. For example, if the flag is used more
than once as an input condition, different statuses may exist within one scan. To
ensure proper execution of the program, the status of the special internal relay
should be copied to a variable at the beginning of the program.
REFERENCE
Please refer to the FPWIN Pro online help for detailed information on using system variables.
Output relays and system variables for FP0R
PLC types
Availability of F171_PulseOutput_Trapezoidal (see page 1322)
Data types
Variable
s_dutDataTable
n_iPulseOutputChannel
Operands
For
s_dutDataTable
n_iPulseOutputChannel
Error flags
No.
IEC address
%MX0.900.7
R9007
%MX0.900.8
R9008
1050
Data type
FP-
, FP-X:
F171_PulseOutput_Trapezoidal_DUT
FP0R:
F171_PulseOutput_Trapezoidal_Type0_DUT
F171_PulseOutput_Trapezoidal_Type1_DUT
decimal constant
Relay
-
-
-
-
-
-
-
-
Set
If
permanently
 channel number or values of the data table are outside the
permissible range
for an instant
 initial speed > target speed
 FP0R/FP-X:pulse output has not been set in the system
registers
Function
Starting address of area containing the
data table
Pulse output channel:
FP-
: 0, 2
FP-X R: 0, 1
FP-X C14T: 0, 1, 2
FP-X C30T/C60T: 0, 1, 2, 3
FP0R: 0, 1, 2, 3
T/C
Register
-
-
DT
-
-
-
-
-
Constant
-
-
-
dec. or hex.