Panasonic FP Series Programming Manual page 906

Hide thumbs Also See for FP Series:
Table of Contents

Advertisement

F167_HighSpeed
Counter_Reset
If the elapsed value of the high-speed counter matches the target value, an interrupt process
Description
immediately turns the specified output to FALSE.
See also: Hsc_TargetValueMatch_Reset (see page 1166)
Characteristics of target value match OFF control
0
-200
2
3
4
-200
Target value
Elapsed value of high-speed counter
1
Execution condition
2
High-speed counter control flag
3
PLC output
4
The PLC output turns to FALSE when the elapsed value matches the target value. In addition, the
high-speed counter control flag turns to FALSE and the instruction is deactivated.
If an output is specified that has not been implemented, only the internal memory of the
corresponding WY address is set or reset.
Interrupt operation
The interrupt program will be executed when the elapsed value matches the target value. Any
interrupt that has been entered into the Tasks list is automatically enabled. A special interrupt
program number is assigned to each channel number.
Channels used by interrupt programs:
PLC type
Interrupt 0
Interrupt 1
Interrupt 2
Target value match OFF (high-speed counter)
1
FP0, FP-e
FP
Channel 0
Channel 0
Channel 1
Channel 1
FP-X (Relay
FP-X
types)
(Transistor
types)
Channel 0
Channel 0
Channel 1
Channel 1
Channel 2
Channel 2
High-speed counter instructions
FP0R
Channel 0
Channel 1
905