H Parameters: Multi-Function Terminals; H Parameters: Multi-Function Terminals; H1: Multi-Function Digital Inputs - YASKAWA A1000 Technical Manual

Hide thumbs Also See for A1000:
Table of Contents

Advertisement

B.7 H Parameters: Multi-Function Terminals
H parameters assign functions to the multi-function input and output terminals.
u

H1: Multi-Function Digital Inputs

No.
(Addr.
Name
Hex)
Multi-Function Digital Input
H1-01
Terminal S1 Function
(438)
Selection
Multi-Function Digital Input
H1-02
Terminal S2 Function
(439)
Selection
Multi-Function Digital Input
H1-03
Terminal S3 Function
(400)
Selection
Multi-Function Digital Input
H1-04
Terminal S4 Function
(401)
Selection
Multi-Function Digital Input
H1-05
Terminal S5 Function
(402)
Selection
Multi-Function Digital Input
H1-06
Terminal S6 Function
(403)
Selection
Multi-Function Digital Input
H1-07
Terminal S7 Function
(404)
Selection
Multi-Function Digital Input
H1-08
Terminal S8 Function
(405)
Selection
<1> Value in parenthesis is the default setting when a 3-Wire initialization is performed (A1-03 = 3330).
H1-oo
Function
Setting
0
3-Wire sequence
1
LOCAL/REMOTE selection
2
External reference 1/2 selection
3
Multi-Step Speed Reference 1
4
Multi-Step Speed Reference 2
5
Multi-Step Speed Reference 3
6
Jog reference selection
7
Accel/decel time selection 1
8
Baseblock command (N.O.)
YASKAWA ELECTRIC TOEP C710616 41B YASKAWA AC Drive - A1000 Quick Start Guide
Description
Assigns a function to the multi-function digital inputs.
Refer to pages
205
to
208
for descriptions of setting values.
Note: Set unused terminals to F.
Assigns a function to the multi-function digital inputs.
Refer to pages
205
to
208
for descriptions of setting values.
Note: Set unused terminals to F.
Assigns a function to the multi-function digital inputs.
Refer to pages
205
to
208
for descriptions of setting values.
Note: Set unused terminals to F.
Assigns a function to the multi-function digital inputs.
Refer to pages
205
to
208
for descriptions of setting values.
Note: Set unused terminals to F.
Assigns a function to the multi-function digital inputs.
Refer to pages
205
to
208
for descriptions of setting values.
Note: Set unused terminals to F.
Assigns a function to the multi-function digital inputs.
Refer to pages
205
to
208
for descriptions of setting values.
Note: Set unused terminals to F.
Assigns a function to the multi-function digital inputs.
Refer to pages
205
to
208
for descriptions of setting values.
Note: Set unused terminals to F.
Assigns a function to the multi-function digital inputs.
Refer to pages
205
to
208
for descriptions of setting values.
Note: Set unused terminals to F.
H1 Multi-Function Digital Input Selections
Closed: Reverse rotation (only if the drive is set up for 3-Wire sequence)
Terminals S1 and S2 are automatically set up for the Run command and Stop command.
Open: REMOTE (parameter settings determine the source of the frequency Reference 1 or 2
(b1-01, b1-02 or b1-15, b1-16)
Closed: LOCAL, digital operator is run and reference source
Open: Run command and frequency reference source 1 (determined by b1-01 and b1-02)
Closed: Run command and frequency reference source 2 (determined by b1-15 and b1-16)
When input terminals are set to Multi-Step Speed References 1 through 3, switching
combinations of those terminals will create a multi-step speed sequence using the frequency
references set in d1-01 through d1-08.
When input terminals are set to Multi-Step Speed References 1 through 3, switching
combinations of those terminals will create a multi-step speed sequence using the frequency
references set in d1-01 through d1-08.
When input terminals are set to Multi-Step Speed References 1 through 3, switching
combinations of those terminals will create a multi-step speed sequence using the frequency
references set in d1-01 through d1-08.
Closed: Jog frequency reference (d1-17) selected. Jog has priority over all other reference
sources.
Used to switch between accel/decel time 1 (set in C1-01, C1-02) and accel/decel time 2 (set
in C1-03, C1-04).
Closed: No drive output
B.7 H Parameters: Multi-Function Terminals
Description
Values
Page
<1>
Default: 40 (F)
104
Min.: 1
Max.: 9F
<1>
Default: 41 (F)
104
Min.: 1
Max.: 9F
Default: 24
Min.: 0
104
Max.: 9F
Default: 14
Min.: 0
104
Max.: 9F
<1>
Default: 3 (0)
104
Min.: 0
Max.: 9F
<1>
Default: 4 (3)
104
Min.: 0
Max.: 9F
<1>
Default: 6 (4)
104
Min.: 0
Max.: 9F
Default: 8
Min.: 0
104
Max.: 9F
Page
105
205
B