Saturn S300 Series Service Manual page 48

Table of Contents

Advertisement

Installation
4.Print Setup by Length Counter
1. Enter <Print Setup-3>, select <Length Counter>. If you can not select
Length Counter, please check the setup of FCU (Refer to the CAUTION of
figure 4-7 in Chapter 4)
2. If the FCU is set correctly, the screen will display like this:
System Status
Printer is off
EEEEEEEEEEE12345678902008/03/05
EEEEEEEEEEE123456789008:40:18
EEEEEEEEEEE1234567890000000205
Counter
Print Control
Length Par
Current length
Ok (F1)
Reset Counter
3.
When counter display "On", it means the function is open.
4.
"Print control": controlled by photocell or "Print" button.
Length Par: set print space. It is used as followed:
Output 2000 pulse signal when rotating once. The rotating circumference
is the same as a wheel with the circumference of 1 meter. Therefore, when
the wheel is touching the product line, one rotating of the wheel equals to
1 meter of the product line moving. In a word, when printing every 1 meter,
set "Length Par" to 2000.
Caution:
Under the status of "Printer is ready to print", length counter'
setting is locked and cannot be changed. Press "Print" and exit the
status of "Printer is ready to print", you may set up parameters of
length counter under any other status.
When "Print Control" is controlled by "Print" to adjust the start or
stop of printing, enter Length Counter after start the printer, choose
"On" or "Off" of the Length counter once, Push "Print" twice to
enter into "Print is ready", then the printer can print normally.
Insert "Serial number" in printing message, the printing effect of Length
counter can be realized.
Caution: According to the model of the printer there are 2 or 4 serial
numbers can be inserted into one message at most.
The procedures of "Insert Serial Number" as below:
1.
Enter<Edit Message-1>, select <Select Font>, confirm the font size of the
serial number.
2.
Enter<Edit Message-2>, select <Insert Serial Number>, it displays as
below:
Setup Encoder
2007/12/13 12:13
On
Print key
5 (2~320000)
0
(F2)
Exit (F3)
Current Flow Time
4-13

Advertisement

Table of Contents
loading

This manual is also suitable for:

S400 seriesS seriesS600 series

Table of Contents