Maintenance
Procedure 6
Flow Time Calibration
Start
Switch on the
power supply.
Ensure the ink tank
has no less than
400 ml ink. Push the
tray into the printer.
Enter <Ink
System-2> select
'Flow time
calibration' to start
calibration.
The viscosity value
will be calculated
after 4 minutes later.
Figure 6-16. Flow Time Calibration (Procedure 6)
Whether the
difference
between 3
tests is less
than 50?
No
Yes
Whether all
the three test
value is "0"?
No
Ensure the printer
refresh the
parameter
automatically, select
EXIT to finish
calibration.
Enter Nozzle Drive
Setup (Procedure 8
)
WARNING: Refer to Ink Maintenance Flow Charts on
page
maintenance procedures.
6-23
If all the three test
value is "0", select
CANCEL to exit,
turn to procedure 5,
and then perform
calibration again.
Yes
6-16