Communication with the PLC
6.6
Fieldbus configuration files
The configuration files for the respective fieldbus systems are located on the supplied CD.
6.6.1
GSD file for Profibus-DP
The GSD file contains the specific configuration data of the slave. The data must be known to the
Profibus master.
The manufacturers of the Profibus master supply the tools for the integration of the GSD file into
the Profibus network. Suitable are for example the Siemens step 7 tools. Roland Electronic does
not supply such tools, because they have to be compatible with the interface design of the master.
The GSD file is supplied on a CD or can be downloaded from the Roland homepage.
By pressing the key "DOWN", status indicators are shown on the display.
ROLAND ELECTRONIC GmbH · Otto-Maurer-Str. 17 · DE 75210 Keltern · Phone +49 (0)7236-9392-0 · Fax +49 (0)7236-9392-33
92
Double Sheet Detector R1000-series I20
with integrated fieldbus interface
24 Bytes I/O must be set.
Note
Nr.
LED
State
LED 1 ---
---
LED 2 Fieldbus
Green
Online
Off
LED 3 Fieldbus
Red
Offline
Off
LED 4 Fieldbus
Off
Diagnostics
Red, flashing (1 Hz)
Red, flashing (2 Hz)
Red, flashing (4 Hz)
Red, flashing (8 Hz)
Manual
Status Indicators
Description
---
Bus online, data exchange possible
Bus not online (or no power)
Bus offline
Bus not offline (or no power)
No diagnostics present (or no power)
Error in Configuration Data
Error in Parameter Data
Error in initialization of the PROFIBUS
communication ASIC
Watchdog timeout (internal error)
B0060191 / Rev. 1.7