Roland R1000 Series Manual page 91

Double sheet detector with integrated fieldbus interface
Hide thumbs Also See for R1000 Series:
Table of Contents

Advertisement

B0060191 / Rev. 1.7
6.5.4
External continuous measurement / External special via external inputs
Measurement Start
Function result
Function fault
BOUT Bus warning
(0-sheet, 1-sheet, 2-sheet)
OUT warning
(0-sheet, 1-sheet, 2-sheet)
Fig. 42: Timing diagram for external continuous measurement / external special via external inputs
1)
In case of "Function fault" = 1 "Function result" will sometimes remain at 0.
*
The status of the 0-,1-,2-sheet and warning outputs are updated via the Fieldbus (BOUT) with a refresh rate of 6 ms.
ROLAND ELECTRONIC GmbH · Otto-Maurer-Str. 17 · DE 75210 Keltern · Phone +49 (0)7236-9392-0 · Fax +49 (0)7236-9392-33
Double Sheet Detector R1000-series I20
with integrated fieldbus interface
IN / BIN
BOUT
1)
BOUT
BOUT
Ready
The output function result is set with the arrival of the first measured
Note
value and remains set.
In the "extern special" measurement mode the highest measured value
Note
will be displayed and held at the outputs until a new measurement is
started.
Manual
"1" if fault
"0" if fault
"0" active
"0" active
*
*
< 15 ms
Communication with the PLC
*
*
< 15 ms
91