Sensors - Roland R1000 Series Manual

Double sheet detector with integrated fieldbus interface
Hide thumbs Also See for R1000 Series:
Table of Contents

Advertisement

Order data
EtherNet/IP
I20-2-EN-S
I20-4-EN-S
I20-2-EN-S-FP
I20-4-EN-S-FP
EtherCAT
I20-2-ET-S
I20-4-ET-S
I20-2-ET-S-FP
I20-4-ET-S-FP
12.2

Sensors

Order information
IS20-30GS
IE20-30GS
IS42-30GS
IE42-30GS
ISQ42S
IEQ42S
ISQ42FS
IEQ42FS
ISQ160S
IEQ160S
ROLAND ELECTRONIC GmbH · Otto-Maurer-Str. 17 · DE 75210 Keltern · Phone +49 (0)7236-9392-0 · Fax +49 (0)7236-9392-33
158
Double Sheet Detector R1000-series I20
with integrated fieldbus interface
2 channels, for max. 2 pairs of sensors of the same type
4 channels, for max. 4 pairs of sensors of the same type
2 channels, for max. 2 pairs of sensors of the same type
4 channels, for max. 4 pairs of sensors of the same type
2 channels, for max. 2 pairs of sensors of the same type
4 channels, for max. 4 pairs of sensors of the same type
2 channels, for max. 2 pairs of sensors of the same type
4 channels, for max. 4 pairs of sensors of the same type
Description
Sensor transmitter 20/40 mm Ø, without cable, with sensor plug for sensor cable connection,
sensor with thread sleeve M30 x 1,5, with 2 flat nuts M30
Sensor receiver 20/40 mm Ø, without cable, with sensor plug for sensor cable connection,
sensor with thread sleeve M30 x 1,5, with 2 flat nuts M30
Sensor transmitter 42 mm Ø, without cable, with sensor plug for sensor cable connection,
sensor with thread sleeve M30 x 1,5, with 2 flat nuts M30
Sensor receiver 42 mm Ø, without cable, with sensor plug for sensor cable connection,
sensor with thread sleeve M30 x 1,5, with 2 flat nuts M30
Sensor transmitter in cubical enclosure with 50 mm installation height, mounting M6 screws,
without cable, with sensor plug for sensor cable connection
Sensor receiver in cubical enclosure with 50 mm installation height, mounting M6 screws,
without cable, with sensor plug for sensor cable connection
Sensor transmitter in cubical enclosure with 50 mm installation height, mounting M6 screws,
fixed cable 0.2 meters wit cable plug for extension cable connection
Sensor receiver in cubical enclosure with 50 mm installation height, mounting M6 screws,
fixed cable 0.2 meters wit cable plug for extension cable connection
Sensor transmitter in cubical enclosure with 36 mm installation height, mounting M4 screws,
without cable, with sensor plug for sensor cable connection
Sensor receiver in cubical enclosure with 36 mm installation height, mounting M4 screws,
without cable, with sensor plug for sensor cable connection
Manual
Control unit in wall mount enclosure,
data backup via EtherNet/IP or USB port
Control unit for front panel mounting,
data backup via EtherNet/IP or USB port
Control unit in wall mount enclosure,
data backup via EtherCAT or USB port
Control unit for front panel mounting,
data backup via EtherCAT or USB port
B0060191 / Rev. 1.7