B0060191 / Rev. 1.7
7.7.2
Program parameters for the (Monitoring Parts for Hardened / Tempered
Properties and Materials Mix up)
This menu structure is valid for the system type g (for details refer to chapter 3.2)
The program parameters contain the information required for the various measurement programs.
For accessing the program parameters, select the mode "configuration program parameter" and
confirm with ENTER.
Program parameter 1: Selecting the measuring program to be configured.
Program Parameter: 1
Program Number
Fig. 68: Selecting the program to be configured
Here the measuring program (1-255) to be configured is selected. All following adjustments apply
to the selected program.
Program parameter 2: Selecting the sensors to be used for measurement.
Program Parameter: 2
Sensor no./ Sequence
Fig. 69: Sensor number / Sequence
Here the sensor pair /sensor pairs is / are selected, which are to be used for measurement.
Possible choices:
1 / 2 / 3 / 4
1+2 / 1+3 / 1+4 / 2+3 / 2+4 / 3+4
1+2+3 / 1+2+4 / 1+3+4 / 2+3+4 / 1+2+3+4
Program parameter 3: Setting the measuring frequency
Program Parameter: 3
frequency
320 Hz
Fig. 70: Setting the measuring frequency
According the measuring task is selected here the frequency. Different frequencies are available,
depending on the sensor type.
Program parameter 4: not available
ROLAND ELECTRONIC GmbH · Otto-Maurer-Str. 17 · DE 75210 Keltern · Phone +49 (0)7236-9392-0 · Fax +49 (0)7236-9392-33
Double Sheet Detector R1000-series I20
with integrated fieldbus interface
1
A change deletes the values determined during the Teach-In and
Note
therefore requires a new Teach-In.
Manual
Start-up
115