Roland R1000 Series Manual page 54

Double sheet detector with integrated fieldbus interface
Hide thumbs Also See for R1000 Series:
Table of Contents

Advertisement

Electrical installation
5.2.3.2
ControlNet
The control unit has two coaxial fieldbus connections "A" and "B" for ControlNet. For normal
applications one connection can be used, for redundant applications both connections must be
used.
The corresponding cable plugs are not within the scope of supply.
Fieldbus type
ControlNet
5.2.3.3
DeviceNet (B-coded)
An M12 plug with inverse coding is used for the DeviceNet connection. A T-connector is not
necessary, because the control unit is equipped with input and output.
The corresponding cable plugs are part of the standard scope of supply.
M12, 5-pin, B-coded, male connector at control unit
2
3
plug side
ROLAND ELECTRONIC GmbH · Otto-Maurer-Str. 17 · DE 75210 Keltern · Phone +49 (0)7236-9392-0 · Fax +49 (0)7236-9392-33
54
Double Sheet Detector R1000-series I20
with integrated fieldbus interface
Allocation of ControlNet connector
If the I20 is the last participant in the bus, then an external termination
Note
resistor should be placed into the open connector. The resistor is not
included in the scope of supply.
Allocation of DeviceNet connection
Input (Pos. C)
1
5
4
View:
Suppliers / types / notes: Binder, type 715 (B-coded) and others
Manual
1
Connector C1 (ControlNet output)
2
Connector C2 (ControlNet input)
Connector C1 "A"
BNC
M12, 5-pin, B-coded, female connector at control unit
Pin 1
shield
Pin 2
V +
Pin 3
V -
Pin 4
CAN High
Pin 5
CAN Low
B0060191 / Rev. 1.7
Connector C2 "B"
BNC
Output (Pos. B)
1
2
5
4
3
View:
plug side