Start-up
This system parameter is only for EtherNet/IP
System Parameter:
EthernetIP DHCP:
Fig. 96: Setting DHCP
System Parameter: 6b
IP:
192.168.
Fig. 97: Setting IP-Address
System Parameter: 6c
Snet: 255.255.255.
Fig. 98: Setting SubNet
System Parameter: 6d
GWay:
0.
Fig. 99: Setting Gateway
System parameter 7: Indicating and setting the Bus baud rate.
System Parameter:
Busbaudrate
500kb
Fig. 100: Indicating and setting the Bus baud rate
Setting the Bus baud rate depends on the Bus type.
Profibus: up to 12Mbps/s; selection at master
ControlNet: -----
DeviceNet: 125/250/500/kBit
CanOpen: 10/20/50/125/250/500/800/1000 kbps
ProfiNet IO: ----
CC-Link: 125/625kbps 2,5/5/10Mbps
EtherNet/IP: – –
EtherCAT: – –
Interbus: 500 kbits/s
ROLAND ELECTRONIC GmbH · Otto-Maurer-Str. 17 · DE 75210 Keltern · Phone +49 (0)7236-9392-0 · Fax +49 (0)7236-9392-33
124
Double Sheet Detector R1000-series I20
with integrated fieldbus interface
6
no
0. 10
0
0.
0.
0
7
Manual
If DHCP is switched on, the IP-setting will done via
DHCP. If DHCP switched off, must the IP-address,
SubNet and Gateway be selected.
Here is the IP-address selected.
Here is the SubNet selected.
Here is the Gateway selected.