Start-up
Static Teach-In 2-sheet:
Program Parameter: 9
Teach-In 2-sheet
feed 2-sheet
then press ENTER
Fig. 65: Teach-In procedure for 2-sheet
The double sheet must be moved into mid-position between the sensors. With the ENTER key the
Teach-In
for 2-sheet
Dynamic Teach-In 2-sheet:
Program Parameter: 9
Teach-In 2-sheet
drive 2-sheet through
then press ENTER
Fig. 66: Teach-In procedure for 2-sheet
The double sheet must be moved through the sensor gap in mid position. With the ENTER key the
measurement value will be stored.
The dynamical Teach-In
After the Teach-In
Program Parameter: 9
Teach-In 2-sheet
finished
push ENTER
Fig. 67: Teach-In finished
ROLAND ELECTRONIC GmbH · Otto-Maurer-Str. 17 · DE 75210 Keltern · Phone +49 (0)7236-9392-0 · Fax +49 (0)7236-9392-33
114
Double Sheet Detector R1000-series I20
with integrated fieldbus interface
The position of the sheet for Teach-In for 2-sheet must match with the
Note
position in measurement operation. Otherwise the measurement result can
become faulty.
will be performed.
for 2-sheet
is suitable especially for magnetical conveyor belt applications.
for 2-sheet
the following message is shown: