3.5

Parameters of the control unit

The I20 provides for extensive configuration. So, different customer requirements can be served.
Configuration is performed by setting system parameters and program parameters.
System parameters are set only once during commissioning, and will then remain unchanged.
Program parameters contain items which are material and job depending, and enable individual
adaptation to the measuring task.
3.5.1
Adjustment parameters
Adjustment parameters are assigned to the individual system. They apply only for this system and
should not be transferred to another unit (control unit exchange).
"Zero adjust"
Before commissioning a new system, after having exchanged a sensor or a sensor cable or a
control unit, a zero adjust must be performed. This zero adjust eliminates the production-related
variations of the sensors. The sensors will be zero adjusted "all in one stroke".
The zero adjustment is valid for all programs and should be performed only once!
"Test sensor distance"
Checks the sensor distances.
"Deviation of distance"
Indicates the deviation from the set sensor distances.
"Sensors distance"
Indicates the determined sensor distances in mm / inch.
"Control sensors"
Test of wiring / allocation of the sensors.
3.5.2
System parameters
"Language"
System languages available for operating the unit via display and keyboard:
German / English / Spanish / Italian / French.
"System type"
Fundamental setting of the system function.
In „Standard" setting the nominal thickness, the material and the electrical conductivity must be
specified.
In the other settings (see chapter 3.2 system type b – f) this specification is not required, therefore
only FE and NF material within the stated thickness range can be measured.
For details refer to chapter 3.2
The "Frequency" is specially designed for the Monitoring Parts for Hardened / Tempered Properties
and Materials Mix up.
The damping mode is a special application.
For details refer to chapter 3.2.
ROLAND ELECTRONIC GmbH · Otto-Maurer-Str. 17 · DE 75210 Keltern · Phone +49 (0)7236-9392-0 · Fax +49 (0)7236-9392-33
Manual
Double Sheet Detector R1000-series I20
with integrated fieldbus interface
System description