Roland R1000 Series Manual page 104

Double sheet detector with integrated fieldbus interface
Hide thumbs Also See for R1000 Series:
Table of Contents

Advertisement

Start-up
7.4.2
Sub structure "Program parameters" (details in 7.7)
7.4.2.1
Sub structure "Program parameters" (except in operating mode "frequency")
Program No.
Sensor number
Nominal thickness
Material
Material
Lower limit value TL
Upper limit value TU
Settling time desired / actual
Teach-in 1-sheet
Teach-in 2-sheet
Fig. 46: Sub structure „program parameters"
ROLAND ELECTRONIC GmbH · Otto-Maurer-Str. 17 · DE 75210 Keltern · Phone +49 (0)7236-9392-0 · Fax +49 (0)7236-9392-33
104
Manual
Double Sheet Detector R1000-series I20
with integrated fieldbus interface
1 ... 255
Sensor number
1 / 2 / 3 / 4 / 1+2 / 1+3 / 1+4 / 2+3 / 2+4 / 3+4 /
1+2+3 / 1+2+4 / 1+3+4 / 2+3+4 / 1+2+3+4
0.000 ... 15.00 mm (only in operating mode „Standard)
– FE
– NF (non-ferrous, with conductivity value)
– NF (non-ferrous, without conductivity, unit detects it)
TL% (0-99%) and absolute
TU% (100-180%) and absolute
2 / 4 / 8 / 15 / 25 / 100 / 250 ms
– ok
– missing
– dynamic all / single
– static all / single
– no
– dynamic all / single
– static all / single
B0060191 / Rev. 1.7