Roland R1000 Series Manual page 93

Double sheet detector with integrated fieldbus interface
Hide thumbs Also See for R1000 Series:
Table of Contents

Advertisement

B0060191 / Rev. 1.7
6.6.2
EDS file for ControlNet
The EDS file contains the specific configuration data of the ControlNet adapter. The data must be
known to the scanner.
The manufacturers of the scanner supply the tools for the integration of the EDS file into the
ControlNet network. Suitable are for example Rockwell RSNetworx configuration tools (starting
from version 1.06). Roland Electronic does not supply such tools, because they have to be
compatible with the interface design of the scanner.
The EDS file is supplied on a CD or can be downloaded from the Roland homepage.
By pressing the key "DOWN", status indicators are shown on the display.
ROLAND ELECTRONIC GmbH · Otto-Maurer-Str. 17 · DE 75210 Keltern · Phone +49 (0)7236-9392-0 · Fax +49 (0)7236-9392-33
Double Sheet Detector R1000-series I20
with integrated fieldbus interface
24 Bytes I/O must be set.
Note
Nr.
LED
State
LED 1 Module
Green
Status
Green, flashing
Red
Red, flashing
LED 2
Channel A
Off
and
and
Red
LED 3
Channel B
Alternating
Red / Green
Red, flashing
LED 2
Channel A
Off
or
or
Green
LED 3
Channel B
Green flashing
Red, flashing
Red & Green
flashing
LED 4 Module
Off
Owned
Red, flashing (1 Hz)
Manual
Status Indicators
Description
Connection in Run State
Connecting Connection Idle
Major fault
Minor fault
Module not initialized
Major fault
Self test
Node configuration error; duplicate Mac ID, etc.
Channel disabled
Normal operation of channel
Temporary error (Node will self correct) or not
configured
No other nodes or media fault
Network configuration error
No connection has been opened
A connection has been opened towards the module
Communication with the PLC
93