Roland R1000 Series Manual page 31

Double sheet detector with integrated fieldbus interface
Hide thumbs Also See for R1000 Series:
Table of Contents

Advertisement

B0060191 / Rev. 1.7
In a window comparator the three signals will be generated from the measuring signal. The signal
"0-sheet" is generated when the measuring signal falls short of the lower switching threshold TL.
The lower switching threshold TL can be set from 1...99%. The signal "2-sheet" is generated when
the upper switching threshold is exceeded. The upper switching threshold TU can be set from
100...180%. If the measuring value is within both limits, the signal "1-sheet" is generated.
Obere Schaltschwelle
Upper switching threshold
Untere Schaltschwelle
Lower switching threshold
Fig. 10: Visualization of switching thresholds
The switching thresholds should be adjusted corresponding to the application.
"Nom./curr. settling time"
Defines the time which the system requires to reach stable measurement results.
For details refer to chapter 3.7.2.
"Teach-In Part A"
The unit calibrates part A to 100%.
The calibration applies only to the currently selected program.
"Teach-In Part B"
The unit calibrates part B to 200%.
The calibration applies only to the currently selected program.
ROLAND ELECTRONIC GmbH · Otto-Maurer-Str. 17 · DE 75210 Keltern · Phone +49 (0)7236-9392-0 · Fax +49 (0)7236-9392-33
Double Sheet Detector R1000-series I20
with integrated fieldbus interface
2
1
Signal
0
Manual
c
Signal range for 0-sheet
Signal range for 1-sheet
b
Signal range for 2-sheet
Upper switching threshold
Lower switching threshold
a
System description
a
b
c
TU
TL
31