B0060191 / Rev. 1.7
S
N
S
Fig. 20: Sensor mounting, top view (*Sensor)
ROLAND ELECTRONIC GmbH · Otto-Maurer-Str. 17 · DE 75210 Keltern · Phone +49 (0)7236-9392-0 · Fax +49 (0)7236-9392-33
Double Sheet Detector R1000-series I20
with integrated fieldbus interface
> 50 cm
S
S
S
N
N
N
N
N
N
S
S
S
The sensors should be mounted wherever possible 50 cm after the
Note
start of the magnetic tape drive.
If electromagnets are used in the conveyor belts, the electromagnets
Note
must be supplied with DC voltage / current. The residual ripple of the
supply voltage must not exceed 5%. The supply voltage or the supply
current of the electromagnets is not be clocked during the
measurement, as this can affect the measurement result.
Manual
S
S
N
N
V
N
N
S
S
Mounting
49