B0060191 / Rev. 1.7
Bytes 12 - 14:
Byte.Bit
PLC –> R1000 (BIN)
12.0
---
12.1
---
12.2
---
12.3
Material detection with sensor 1
12.4
---
12.5
---
12.6
---
12.7
---
13.0
---
13.1
---
13.2
---
13.3
---
13.4
---
13.5
---
13.6
---
13.7
---
14.0
---
14.1
---
14.2
---
14.3
Teach-In 1-sheet sensor 1
14.4
Teach-In 2-sheet sensor 1
14.5
---
14.6
---
14.7
Teach-In Range sensor 1
2), 4)
Footnotes see chart "Byte 21 to 23"
Bytes 15 - 17:
Byte.Bit
PLC –> R1000 (BIN)
15.0
---
15.1
---
15.2
---
15.3
Material detection with sensor 2
15.4
---
15.5
---
15.6
---
15.7
---
16.0
---
16.1
---
16.2
---
16.3
---
16.4
---
16.5
---
16.6
---
16.7
---
17.0
---
17.1
---
17.2
---
17.3
Teach-In 1-sheet sensor 2
17.4
Teach-In 2-sheet sensor 2
17.5
---
17.6
---
17.7
Teach-In Range sensor 2
1), 2), 3), 4)
Footnotes see chart "Byte 21 to 23"
ROLAND ELECTRONIC GmbH · Otto-Maurer-Str. 17 · DE 75210 Keltern · Phone +49 (0)7236-9392-0 · Fax +49 (0)7236-9392-33
Manual
Double Sheet Detector R1000-series I20
with integrated fieldbus interface
R1000 -> PLC (BOUT)
Type of material at sensor 2 (1=FE, 0=NF)
Current measuring program S2: Teach-In performed
---
---
Warning
0-sheet
1-sheet
2-sheet
High byte thickness value
Low byte thickness value
Communication with the PLC
R1000 –> PLC (BOUT)
Type of material at sensor 1 (1=FE, 0=NF)
Current measuring program S1: Teach-In performed
---
---
2)
Warning
2)
0-sheet
sensor 1
2)
1-sheet
sensor 1
2)
2-sheet
sensor 1
4)
High byte thickness value
(sensor 1)
4)
Low byte thickness value
(sensor 1)
2)
2)
sensor 2
2)
sensor 2
2)
sensor 2
4)
(sensor 2)
4)
(sensor 2)