Communication with the PLC
EDS file for EtherNet/IP
6.6.7
The EDS file contains the specific configuration data of the device. The data must be known to the
controller.
The manufacturers of the controller supply the tools for the integration of the EDS file into the
network. Roland Electronic does not supply such tools, because they have to be compatible with
the interface design of the controller.
The EDS file is supplied on a CD or can be downloaded from the Roland homepage.
By pressing the key "DOWN", status indicators are shown on the display.
ROLAND ELECTRONIC GmbH · Otto-Maurer-Str. 17 · DE 75210 Keltern · Phone +49 (0)7236-9392-0 · Fax +49 (0)7236-9392-33
98
Double Sheet Detector R1000-series I20
with integrated fieldbus interface
24 Bytes I/O must be set.
Note
Nr.
LED
LED 1 Link (Activity) LED configuration 1 (Default)
LED 2 Module
Status
LED 3 Network
Status
LED 4 Activity
Status
Manual
Status Indicators
State
Description
Off
Link not sensed
Green
Link sensed
LED configuration 3 (Default)
Off
No power
Green
Controlled by a scanner in Run state
Green, flashing
Not controlled, or scanner in Idle state
Red, flashing
A minor recoverable fault has been detected
Red
A major unrecoverable fault has been detected
Alternating
Self test in progress
Red / Green
LED configuration 3 (Default)
Off
No power or no IP address
Green
On line, one or more connections established
(CIP Class 1 or 3)
Green, flashing
On line, no connections established
Red
Duplicate IP address, fatal error
Red, flashing
One or more connections timed out
(CIP Class 1 or 3)
Alternating
Self-test in progress
Red / Green
Green, flashing
The activity led flashes green each time a packet
is received or transmitted