Technical data
2.3.4
Sensor pair ISQ160S / IEQ160S
Technical data
Application:
Sheet thickness:
Sensor distance:
Measurement principle: Eddy current
Protection class:
Weight:
Material of enclosure:
Sensor cable:
2.3.5
Sensor diagrams
Sensor diagrams are available for determining the admissible measuring range depending on the
gap between transmitter and receiver (Ax) and the material. Ax is specified as follows:
Fig. 1: Transmitter-receiver gap Ax
The marked areas represent the working ranges of the sensors. For all combinations of sheet
thickness and sensor distance Ax within the range a double sheet condition will be reliably
detected, if the switching thresholds are set "tight".
The working ranges of the sensors depend very much on the material properties, they can deviate
from the sensor diagrams shown below.
ROLAND ELECTRONIC GmbH · Otto-Maurer-Str. 17 · DE 75210 Keltern · Phone +49 (0)7236-9392-0 · Fax +49 (0)7236-9392-33
14
Double Sheet Detector R1000-series I20
with integrated fieldbus interface
Part inspection, Material inspection, Hardness inspection
Depending on the application
20 – 80 mm (depending on the application)
IP54
ca. 0.50 kg (1.1 lbs)
Plastic
Quick disconnect
The stated measurement ranges are only valid for systems in „Standard"
Note
setting. For details refer to chapter 3.2.
Ax
Schema_Ax.wmf
The stated measurement ranges are only valid for systems in „Standard"
Note
setting. For details refer to chapter 3.2.