Communication with the PLC
6.6.5
GSD file for ProfiNet IO
The GSD file contains the specific configuration data of the device. The data must be known to the
Profibus controller.
The manufacturers of the controller supply the tools for the integration of the GSD file into the
network. Roland Electronic does not supply such tools, because they have to be compatible with
the interface design of the controller.
The GSD file is supplied on a CD or can be downloaded from the Roland homepage.
By pressing the key "DOWN", status indicators are shown on the display.
ROLAND ELECTRONIC GmbH · Otto-Maurer-Str. 17 · DE 75210 Keltern · Phone +49 (0)7236-9392-0 · Fax +49 (0)7236-9392-33
96
Double Sheet Detector R1000-series I20
with integrated fieldbus interface
24 Bytes I/O must be set.
Note
Nr.
LED
State
LED 1 Link /
Green
Activity
Green, flashing
Off
LED 2 Communi-
Green
cation
Status
Green, 1 flash
Off
LED 3 Module
Green
Status
Green, 1 flash
Green, 2 flashes
Red , 1 flash
Red, 3 flashes
Red, 4 flashes
Off
LED 4 ---
---
Manual
Status Indicators
Description
Link established
Receiving/Transmitting data
No link or power off
On line, Run
- Connection with IO Controller established
- IO Controller is in RUN state
On line, STOP
- Connection with IO Controller established
- IO Controller in STOP state
Off line
- No connection to IO Controller
Initialized, no error
Diagnostic data available
Blink. Used by an engineering tool to identify the
Anybus module
Configuration error
- Too many modules / submodules
- IO size derived from IO Controller too large
- Configuration mismatch ( no module, wrong module)
No Stations Name or no IP-Address assigned
Internal error
No power or not initialized
---
B0060191 / Rev. 1.7