B0060191 / Rev. 1.7
System parameter 3: Selecting the dimensions for the display (mm / inch).
When changing the measurement dimensions, then the sheet metal thicknesses of the stored
program parameters are also converted into the new dimension.
System Parameter:
display value in
Fig. 92: Selecting the dimension for the display
Possible choices:
mm / inch
%mm / %inch only if system type is not "standard".
System parameter 4: Selecting the dimensions for output via fieldbus (mm / inch).
When changing the measurement dimensions, then the sheet metal thicknesses of the stored
program parameters are also converted into the new dimension.
System Parameter:
bus readout value in
Fig. 93: Selecting the dimensions for the fieldbus output
Possible choices:
mm / inch
%
System parameter 5: Setting the display time
System Parameter:
display time
2.0 s
Fig. 94: Setting the display time
The maximal measured values (peak values) will be indicated for the time specified here (holding
time). This time is only for the display.
System parameter 6: Setting the bus address.
System Parameter:
Bus address
Fig. 95: Setting the fieldbus address
Profibus:
ControlNet:
DeviceNet:
CanOpen:
ProfiNet IO:
CC-Link:
EtherNet/IP:
EtherCAT:
ROLAND ELECTRONIC GmbH · Otto-Maurer-Str. 17 · DE 75210 Keltern · Phone +49 (0)7236-9392-0 · Fax +49 (0)7236-9392-33
Double Sheet Detector R1000-series I20
with integrated fieldbus interface
3
mm
only if system type is "standard".
4
mm
only if system type is "standard".
only if system type is not "standard".
5
6
1
1 - 125
0 - 99
0 - 63
1 - 127
---
1 – 63
---
---
Manual
Start-up
123

Advertisement