Start-up
System parameter 15: Specifying the system reaction when 2-sheet is detected.
System Parameter: 15
hold if 2-sheets
Fig. 108: Adjusting the 2-sheet reaction
Possible choice:
no:
yes:
System parameter 16: Programming the "Measurement start" inputs under external control.
System Parameter: 16
external meas. start
Fig. 109: Adjusting the measurement start inputs
Possible operating conditions:
IN0:
IN0 + IN1:
IN0 + IN1 + IN2:
System parameter 17: Setting the output logic (0-sheet, 1-sheet, 2-sheet and warning outputs).
System Parameter: 17
Output 0-1-2-warning
24V active
Fig. 110: Setting the output logic
Possible choices:
0 V:
+24 V: The outputs 0-sheet, 1-sheet, 2-sheet and warning are inverted, i.e. the respective
System parameter 18: Setting the method of program selection.
ROLAND ELECTRONIC GmbH · Otto-Maurer-Str. 17 · DE 75210 Keltern · Phone +49 (0)7236-9392-0 · Fax +49 (0)7236-9392-33
128
Double Sheet Detector R1000-series I20
with integrated fieldbus interface
no
The outputs (0-sheet, 1-sheet and 2-sheet) are activated according to the number of
sheets between the sensors. The equipment does not block operation if double
sheet is encountered.
The outputs (0-sheet, 1-sheet and 2-sheet) are activated according to the number of
sheets between the sensors. If double sheet is detected, the output "2-sheet" is
activated and the equipment is blocked until the 2-sheet condition is cleared.
This condition can be cleared
- through the PLC (clear 2-sheet)
- through the keyboard
IN0
If 24 VDC is applied to IN0, then the measurement is executed.
If 0 VDC is applied to this input then the measurement is stopped.
The measurement is performed only, if 24 VDC is applied
simultaneously to IN0 and IN1.
The measurement takes place only, if 24 VDC is applied
simultaneously to IN0 and IN1 and IN2.
As shown in the timing diagrams and the wiring diagrams
signals in the timing diagrams and wiring diagrams must be seen inverted.
The output "Enable" is not affected thereby.
Note
Manual
B0060191 / Rev. 1.7