B0060191 / Rev. 1.7
Static Teach-In 1-sheet:
Program Parameter: 8
Teach-In 1-sheet
feed 1-sheet
then press ENTER
Fig. 61: Teach-In procedure for 1-sheet
The sheet must be moved into mid-position between the sensors. With the ENTER key the
Teach-In
for 1-sheet
Dynamic Teach-In 1-sheet:
Program Parameter: 8
Teach-In 1-sheet
drive 1-sheet through
then press ENTER
Fig. 62: Teach-In procedure for 1-sheet
The sheet must be moved through the sensor gap in mid position. With the ENTER key the
measurement value will be stored.
The dynamical Teach-In
After the Teach-In
Program Parameter: 8
Teach-In 1-sheet
finished
push ENTER
Fig. 63: Teach-In finished
Program parameter 9: Teach-In for 2-sheet
Program Parameter: 9
Teach-In 2-sheet
Fig. 64: Status of Teach-In
Possible indications:
no:
static:
dynamic:
If a Teach-In for 2-sheet is to be repeated, select "static" resp. "dynamical".
static: The system will perform a punctual Teach-In for 2-sheet.
dynamic:
ROLAND ELECTRONIC GmbH · Otto-Maurer-Str. 17 · DE 75210 Keltern · Phone +49 (0)7236-9392-0 · Fax +49 (0)7236-9392-33
Double Sheet Detector R1000-series I20
with integrated fieldbus interface
will be performed.
for 1-sheet
is suitable especially for magnetical conveyor belt applications.
for 1-sheet
the following message is shown:
ok
No Teach-In for 2-sheet is to be performed
A static Teach-In for 2-sheet will be performed
A dynamical Teach-In for 2-sheet will be performed
The double sheet with nominal thickness is moved through the sensor gap
while performing the Teach-In for 2-sheet.
Manual
Start-up
113