System description
"IN / OUT PLC voltage"
Monitores the external 24V voltage from the PLC.
If "monitoring" is set and the PLC voltage is not connected, an error condition is detected therefore.
"External Adjust"
Determines whether an external Teach-In / zero adjust is to be possible. If "yes" is set, the PLC can
trigger the procedure via the inputs "Teach-In 0-, 1-sheet".
Default setting is "no".
The external adjust may only be performed under supervision of an operator.
"Internal analog zero"
Only for service personnel.
"Internal analog gain"
Only for service personnel.
„MAC ID"
Display of the MAC ID for Profinet Bus systems.
"IN/OUT Busproc. data"
Display of the Bus process data. Helpful during commissioning with Fieldbus connected.
"Diagnostic"
Diagnostics of the factors determined during the Teach-In. No default setting.
"Compensation factor"
Projected function.
"System info"
Displays the versions of Software and Hardware as well as the Bus information.
Identifies the control unit.
This information need to be at hand for telephone support.
ROLAND ELECTRONIC GmbH · Otto-Maurer-Str. 17 · DE 75210 Keltern · Phone +49 (0)7236-9392-0 · Fax +49 (0)7236-9392-33
28
Manual
Double Sheet Detector R1000-series I20
with integrated fieldbus interface
B0060191 / Rev. 1.7