Roland R1000 Series Manual page 16

Double sheet detector with integrated fieldbus interface
Hide thumbs Also See for R1000 Series:
Table of Contents

Advertisement

Technical data
Ax / mm
Ax (2 n)
8 0
6 0
Ax (n)
4 0
Ax (½ n)
2 0
0
0,15
1
2
Ax / mm
Ax (2 n)
8 0
7 0
6 0
5 0
Ax (n)
4 0
3 0
Ax (½ n)
2 0
0
0,1
1
Ax / mm
Ax (2 n)
8 0
7 0
6 0
5 0
Ax (n)
4 0
3 0
Ax (½ n)
2 0
0
0 ,4
1
Fig. 3: Sensor diagrams for sensors IS / IE42-30GS / ISQ / IEQ42S
Ax diagrams for sensors ISQ / IEQ160S
The sensors are specifically designed for Monitoring Parts for Hardened / Tempered Properties
and Materials Mix up. The sensor gap can range from 20 to 80 mm depending on the geometry of
the parts to be tested.
ROLAND ELECTRONIC GmbH · Otto-Maurer-Str. 17 · DE 75210 Keltern · Phone +49 (0)7236-9392-0 · Fax +49 (0)7236-9392-33
16
Double Sheet Detector R1000-series I20
with integrated fieldbus interface
STEEL
Ax(n ) = n o min a l se n so r g a p
3
4
5
6
7
8
Sh e e t th ickn e ss / mm
AL U MIN U M
2
3
4
5
6
STAIN L ESS STEEL (Au ste n itic)
2
3
4
5
6
The stated measurement ranges are only valid for systems in „Standard"
Note
setting. For details refer to chapter 3.2.
If more than 1 pair of sensors is connected to the system, the sensor
Note
gaps may not deviate from each other more than ±10%. Otherwise the
zero adjustment can be faulty.
Example: S1: 40 mm
All values are within ±10%.
Manual
7
8
9
1 0
11
1 2
7
8
9
1 0
11
1 2
S2: 42 mm
B0060191 / Rev. 1.7
1 3
1 4
1 5
1 6
Sh e e t th ickn e ss / mm
1 3
1 4
1 5
1 6
Sh e e t th ickn e ss / mm
S3: 39 mm
S4: 43 mm

Advertisement

Table of Contents
loading

This manual is also suitable for:

L20