Roland R1000 Series Manual page 57

Double sheet detector with integrated fieldbus interface
Hide thumbs Also See for R1000 Series:
Table of Contents

Advertisement

B0060191 / Rev. 1.7
5.2.3.9
EtherNet/IP
The EthernetI/P connection is implemented as 1-Port.
2
1
4
View plug side
5.2.3.10 EtherCAT
5.2.4
Connection of Optocoupler outputs (connection D)
The corresponding cable plugs are part of the standard scope of supply.
Connector at control unit
Optocoupler output
1
7
8
6
5
ROLAND ELECTRONIC GmbH · Otto-Maurer-Str. 17 · DE 75210 Keltern · Phone +49 (0)7236-9392-0 · Fax +49 (0)7236-9392-33
Double Sheet Detector R1000-series I20
with integrated fieldbus interface
Allocation of EthernetI/P connection
Round-shape connector, M12, 4-pin., D-coded, socket contact at control unit (Pos. C)
3
Plug enclosure
The corresponding cable plugs are part of the standard scope of supply.
Allocation of EtherCAT connection
Round-shape connector, M12, 4-pin., D-coded, socket contact at control unit
IN (Pos. C)
2
1
3
4
Pin 1
Pin 2
Pin 3
Pin 4
Plug enclosure
The corresponding cable plugs are part of the standard scope of supply.
The Optocoupler inputs are placed at the supply voltage connection
Note
(pos. A)
Allocation of optocoupler outputs
M8, 8-pin, A-coded, female
connector at control unit
pin 1
pin 2
pin 3
2
pin 4
3
pin 5
4
pin 6
pin 7
pin 8
Pin 7 is connected with pin 6 of connection A.
Note
Pin 1 is connected with pin 7 of connection A.
Manual
Pin 1
Pin 2
Pin 3
Pin 4
View: Plug side
+24VDC PLC
OUT0
OUT1
OUT2
OUT3
OUT4
GND PLC
Shield / ground
Electrical installation
TD +
RD +
TD –
RD –
Shield
OUT (Pos. B)
2
1
3
4
TD +
RD +
TD –
RD –
Shield
Suppliers / types / notes:
Binder type 713 and others
External supply 24V DC PLC
1st optocoupler output
2nd optocoupler output
3rd optocoupler output
4th optocoupler output
5th optocoupler output
External supply GND PLC
Internal at enclosure (common)
57