System description
"Display value in..."
Switches the indication of the thickness values on the display between mm  inch.
"Bus readout value"
Switches the outfeeding of the thickness values via Field bus between mm  inch.
"Display time"
Specifies the holding time for the screen display.
Value range 0.0...2 seconds.
"Bus address"
Sets the bus address, as far as a participant address is required for Field bus.
Value range 1...125
"Baud rate Fieldbus"
Sets the Baud rate of the Fieldbus (if required).
In case of EtherNet/IP: DHCP/IP/SUBNET/GATEWAY
"CLR parameter (Clear Program Parameter)"
Deletes all program parameters and all Teach-In data. For doing so, the parameter needs to be set
to "yes". Executing the command requires several minutes, because the program memory will
completely cleared. All program parameters will be reset to the default values and existing Teach-
In data will be deleted. Using this function only makes sense if a unit is to be newly used for
another machine.
"Password active"
Switches the password request on/off. If the password request is set "on", the system / program
parameters can only be changed after the password has been entered.
"Password"
Without password the system data are unprotected against unwanted change. Therefore a
password should be set as soon as the installation is completed and regular operation has
commenced. The factory preset password is "0000", it can be set to a value between 0000 and
9999.
"Pairs of sensors"
Defines the number of connected sensors. Those sensors are then available for measuring. To a 2-
channel system I20-2 max. 2 pairs of sensors can be connected, at a 4-channel system I20-4 max.
4 pairs of sensors can be connected.
"Sensor type"
Currently the sensors IS/IE20-30S or IS/IE42-30S and ISQ/IEQ42FS or ISQ / IEQ160S are
available. For those sensors characteristic curves for linearization purposes exists.
ROLAND ELECTRONIC GmbH · Otto-Maurer-Str. 17 · DE 75210 Keltern · Phone +49 (0)7236-9392-0 · Fax +49 (0)7236-9392-33
26
Manual
Double Sheet Detector R1000-series I20
with integrated fieldbus interface
B0060191 / Rev. 1.7