Ipv6 Neighbor Binding - Cisco Sx350 Cli Manual

Hide thumbs Also See for Sx350:
Table of Contents

Advertisement

29
659

29.38 ipv6 neighbor binding

To globally enable the Neighbor Binding (NB) integrity feature on a VLAN, use the
ipv6 neighbor binding command in VLAN Configuration mode. To return to the
default, use the no form of this command.
Syntax
ipv6 neighbor binding
no ipv6 neighbor binding
Parameters
N/A
Default Configuration
NB integrity on a VLAN is disabled.
Command Mode
Interface (VLAN) Configuration mode
User Guidelines
NB integrity establishes binding for neighbors connected to the perimetrical ports
(see the
device-role (Neighbor Binding)
which the feature is enabled.
Examples
Example 1—The following example enables NB integrity on VLAN 100:
switchxxxxxx(config)#
switchxxxxxx(config-if)#
switchxxxxxx(config-if)#
Example 2—The following example enables NB integrity on VLANs 100-107:
switchxxxxxx(config)#
switchxxxxxx(config-if-range)#
command) belonging to the VLANs on
interface vlan 100
ipv6 neighbor binding
exit
interface range vlan 100-107
ipv6 neighbor binding
Cisco Sx350 Ph. 2.2.5 Devices - Command Line Interface Reference Guide
IPv6 First Hop Security

Advertisement

Table of Contents
loading

Table of Contents