16
. BATTERY/CHARGING SYSTEM
(DINK 50)
REGULATOR/RECTIFIER INSPECTION
Remove the front cover.
Disconnect the regulator/rectifier wire coupler
and remove the nut to remove the
regulator/rectifier.
Measure the resistances between the terminals.
Replace the regulator/rectifier if the readings are
not within the specifications in the table below.
*
• Due to the semiconductor in circuit, it
is necessary to use a specified tester
for accurate testing. Use of an
improper tester in an improper range
may give false readings.
Probe⊕
A (R)
B (W)
Probe(-)
A (R)
3-4MΩ
B (W)
6-8MΩ
∞
C (Y)
∞
D (G)
16-13
C (Y)
D (G)
∞
∞
∞
∞
∞
14-15MΩ
∞
14-15MΩ
Nut
A (Red)
B (White)
DINK50/ 125
Regulator/Rectifier
Coupler
C (Yellow)
D (Green)