16
. BATTERY/CHARGING SYSTEM

VOLTAGE INSPECTION

Remove the battery cover (last page).
Measure the battery voltage using a
commercially available digital multimeter.
Voltage (20ºC/68ºC):
Fully charged: 13-13.2 V
Under charged: below 12.3 V

BATTERY CHARGING

Remove the battery (page 16-4).
Connect the charger positive (+) cable to the
battery positive (+) terminal.
Connect the charger negative (-) cable to the
battery negative (-) terminal.
Turn the power ON/OFF at the chatger,
not at the battery terminals.
Charging current time:
Standard: 0.8 A/5-10 hours
Quick: 4 A/1 hours
Quick charging should only be done in an
emergency; slow charging is preferred.
For battery charging, do not exceed the
charging current and time specified on the
battery. Using excessive current or extending
the charging time may damage the battery.
16-7