C.2.
DOS Software Operating Panel—OL600e & OL610e
The diagnostic and adjustment controls on the DOS Operating Panel are on the Settings tab,
available to the end user, and the Service tab, available to service personnel only.
The Operating Panel uses Windows-type controls and displays.
C.2.1

Settings Tab

Selected controls on the Settings tab perform adjustment and resetting functions. This tab is
avialble to the end user.
At the DOS prompt, enter OL600. When the Operator Panel appears, click on Settings or press
the ALT and S keys.
Reset Item
Click on the item to be reset, then click on Reset.
(1) EEPROM
Resets all EEPROM areas, including Menu level-2, to the factory default values.
The following items are not reset:
Head drive time setting
Fine adjustment of printing start position
Standard tray paper feed amount setting
(2) Menu
Resets all level-1 menu settings to factory fefault values, including all available emula-
tions and options.
(3) Drum Count
Resets the drum life data. Perform this function whenever the image drum is replaced.
Print Position Adjust
Adjusts the horizontal and vertical printing position of the first character of the first line on the
page.
Range of settings: -2.00mm to +2.00mm, in 0.25mm increments.