3.3.18 Manual Feed Guide Assembly

(1) Remove the upper cover (see 3.3.1).
(2) Open the manual feed guide assembly 1, and release the engagement on both sides with the
main unit by carefully bending the manual feed guide assembly 1.
Note: When re-mounting, verify the proper the engagements as shown in the diagram.
Put into the post.
Put into the groove.
1