%3.2.05 Operator Panel Assembly

3.2.05 Operator Panel Assembly
1. Remove the upper cover assembly (3.2.04).
2. Disconnect the operator panel cable (1) from CN10 (2) on the control board.
3. Remove the two mounting screws (3).
4. Detach the operator panel holder (4) by moving it upward, and then pulling toward the front of the
printer.
5. Open the eleven claws and detach the operator panel (5) from the operator panel holder.
P/N 50100001 Panel: Operator ML395 RSPL B.2.03
P/N 50910505 Spring: Cover Open RSPL B.2.03
P/N 55071701 PCB: TFOP Op Panel RSPL B.2.03
P/N 56212601 Switch: Interlock (Assembly) RSPL B.2.03, 12
P/N 56614301 Cable: Microswitch RSPL B.2.03, 12 (Cover Open)
P/N 56628403 Cable: Op (ML395) RSPL B.2.03
ML395 ( 96-02-03 )